Environmental Protection

Standard Solenoids are designed to meet normal environmental and operating conditions encountered in conventional industrial applications: Humidity/Water Splash—Coil area is protected and exposed surfaces plated to withstand occasional water splash and normal in-plant ambient humidity conditions. For continuous high-humidity exposure or water immersion, special encapsulated or molded-coil constructions are available. For extreme environmental conditions, hermetically

Duty Cycle

A comparison of the time a solenoid is energized to the time it is de-energized, expressed as a percentage: Duty Cycle % = [(ON time) / (ON time + OFF time)] x 100. For a given force / stroke requirement the smaller the duty cycle percentage, the smaller the Solenoid.

DURO-TECH®

Electromechanical Solenoids engineered to offer operational durability in extreme conditions. These environmentally protected Solenoids are designed to block contamination, offer vibration resistance, and provide corrosion protection in challenging environments.

Dielectric

The resistance between the coil and the case. Minimum dielectric value is 500 VRMS and ranges up to 1,500 VRMS depending on the solenoid size, type and wire gauge. Dielectric values are shown for each Solenoid in the specifications chart.